24V 230Ah V2-T Elite Series LiFePO4 Battery (5.89kWh)
24V 230Ah V2-T Elite Series LiFePO4 Battery (5.89kWh)
24V 230Ah V2-T Elite Series LiFePO4 Battery (5.89kWh)
24V 230Ah V2-T Elite Series LiFePO4 Battery (5.89kWh)
24V 230Ah V2-T Elite Series LiFePO4 Battery (5.89kWh)
24V 230Ah V2-T Elite Series LiFePO4 Battery (5.89kWh)

24V 230Ah V2-T Elite Series LiFePO4 Battery (5.89kWh)

Regular price$2,599.00
/
Shipping calculated at checkout.

Class-T protection · Victron CAN · Heated · Bluetooth

Epoch 24V 230Ah V2-T Elite Series LiFePO4 | Built-In Fuse, Victron & BT

A premium 5.89kWh lithium battery for advanced marine, RV, Victron, and 24V off-grid solar systems.

The Epoch 24V 230Ah V2-T Elite is a high-capacity 24V 230Ah LiFePO4 battery engineered around a user-serviceable 300A Class-T fuse, native Victron CANBus communication, internal heating, Bluetooth monitoring, and an IP67 enclosure. Its 5.89kWh energy platform gives system builders a compact, managed battery for demanding marine house banks, RV power systems, and professional off-grid energy storage.

230Ah
Capacity
5.89kWh
Stored energy
115A
Continuous output
300A
Class-T fuse
IP67
Ingress rating
16×
Parallel limit

Built for demanding 24V energy systems

11-year limited warranty 5 yrs free repair or replacement
Victron ready CAN and DVCC integration
Internal heating Cold-weather charging support
Bluetooth monitoring Epoch Cloud app and included gauge
Certified cells UL1642, UL9540A and IEC 62619:2022
Serviceable fuse Protected top access

A 5.89kWh Energy Vault for Marine and Off-Grid Systems

Premium 24V storage with source protection, managed communications, and scalable architecture.

The V2-T platform is intended for deep-cycle house-power and energy-storage service rather than engine starting. One battery provides 230Ah at 25.6V nominal and supports large 24V loads without the complexity of wiring several smaller batteries in parallel.

The integrated fuse, CAN communication, remote gauge, external power control, heating, and Bluetooth monitoring reduce installation clutter—but installers must still provide the main disconnect, properly selected downstream overcurrent protection, branch fusing, busbars, conductors, securement, precharge where required, and a complete commissioning plan.

Safety: The V2-T Class T Fuse

High-interrupt source protection, managed BMS safeguards, and a sealed serviceable enclosure.

User-Serviceable 300A Class-T Fuse

The Eaton Bussmann JJN-300 has a 20kA interrupting rating at 160V DC and sits under a protected service cover on the lid. It reduces fault energy at the battery outlet, but it does not replace the main disconnect or downstream cable and branch protection: install a DC-rated fuse or breaker in the positive conductor, as close to the battery as practical.

Advanced BMS and Published Safety Listings

The embedded BMS supervises cell voltage, current, temperature, protection events, and balancing. Epoch publishes UL1642, UL9540A, and IEC 62619:2022 cell references, plus CE, RoHS, and fuse-related listing information.

IP67 Dust-Tight, Immersion-Rated Enclosure

The enclosure is dust-tight and rated for temporary immersion up to 1 meter for up to 30 minutes when every seal and gland is correctly installed. Treat IP67 as an ingress-protection test rating—not permission for permanent submersion, standing-water installation, water jets or pressure washing. Install the battery where it stays dry in normal use.

Premium Smart Features and Seamless Integration

Managed Victron charging, cold-weather operation, and real-time battery visibility.

Native Victron Integration via CANBus

The BMS communicates at 500kbit/s through the specified battery harness. A correctly configured Cerbo GX or Ekrano GX can use Epoch as the controlling BMS and battery monitor with DVCC enabled, allowing the battery to publish managed operating data and charging limits to the Victron system.

Cold-Weather Ready with Internal Heating

The 153.6W heater is controlled by the BMS. The cells are not charged below 0°C (32°F); while charging, the heater switches on at 5°C (41°F) and off at 10°C (50°F), using incoming charge energy to warm the cells before normal charging proceeds.

Bluetooth App and Physical Monitoring

Monitor state of charge, cell voltage, temperature, charge and discharge cycles and system health alerts in the Epoch Cloud app (iOS and Android), over Bluetooth 4.0 through the included battery gauge. The included remote digital gauge and external power button provide local access without opening the battery compartment.

Unrelenting Power and Massive Scalability

High-capacity standalone power with supported series or parallel expansion.

A single battery supports 115A continuous discharge (about 2,944W DC before inverter losses) and 250A for 5 seconds. Size inverters by their DC input current: a 2,000W load through a 90%-efficient inverter draws about 87A. If an inverter's continuous DC input can exceed 115A, add batteries in parallel. Uses include marine hotel loads, 24V trolling-motor and electric auxiliary systems where requirements match, and off-grid loads.

Scale to sixteen batteries in parallel for 3,680Ah and about 94.21kWh at 25.6V nominal, or use up to two matched batteries in series for a 51.2V nominal (48V-class) string, 58.0V at full charge. Mixed series-parallel banks are not supported.

Compatible applications

Marine, Victron, RV, solar, off-grid, and high-capacity 24V power systems.

  • ✓ 24V off-grid solar systems for cabins, remote sites, backup power, and stationary energy storage.
  • ✓ Victron-based systems using compatible Cerbo GX or Ekrano GX devices and managed BMS communication.
  • ✓ Marine house banks for electronics, refrigeration, pumps, navigation, lighting, and other hotel loads.
  • ✓ Large RV, expedition vehicle, and commercial mobile power systems using 24V inverter/chargers.
  • ✓ 24V trolling-motor or electric auxiliary systems where current, voltage, charging, and manufacturer requirements match.
  • ✓ Replacing a Group 8D lead-acid battery, after confirming tray fit, hold-down and lid clearance against 20.86 × 8.65 × 12.06 in.
  • ✓ Parallel banks up to sixteen batteries for larger 24V energy-storage systems.
  • ✓ Series strings of up to two batteries (51.2V nominal, 48V class), installed to the C24230A-A user manual.

V2-T Elite features

Professional-grade source protection, communications, monitoring, and environmental capability.

300A Eaton Class-T fuse User-serviceable JJN-300 source fuse with a published 20kA interrupt rating at 160VDC.
115A continuous discharge Approximately 2.94kW of nominal DC output from one 25.6V battery before conversion losses.
115A continuous charging 115A continuous (180A for 5 seconds) from lithium-compatible CC/CV equipment programmed to 28.4V absorption and 27.0V float.
Victron CAN communication Managed battery data and DVCC-based charge control through a correctly configured GX system.
IP67 enclosure Dust-tight and temporary-immersion rated when all seals and glands are properly installed.
153.6W internal heater BMS-controlled 153.6W heater: on at 5°C and off at 10°C while charging; the cells are not charged below 0°C.
Bluetooth app monitoring Track state of charge, cell voltage, temperature, cycles, and system alerts in the Epoch Cloud app.
External controls included Mountable power button and remote digital battery gauge simplify access and status checks.
Advanced BMS protection Monitors cell voltage, current, temperature, overcharge, over-discharge, and short-circuit conditions.
Passive convection cooling No liquid cooling loop or serviceable cooling fan required.
Series or parallel support Up to two in series or sixteen in parallel; mixed series-parallel is not supported.
Certified components Published UL1642/UL9540A/IEC 62619:2022 cell, CE, RoHS, and fuse-related listings.

Recommended system components

Complete the installation with approved mounting, communications, charging, distribution, and service components.

Elite Series 8D mounting hardware Official fitment support for C24230A-A securement in mobile and stationary installations.
Victron Cerbo GX or Ekrano GX System control, DVCC, alarms, local display, and VRM remote monitoring.
Included: Epoch/Victron communication harness Use the specified grey RJ45 BMS lead and battery daisy-chain harness rather than assuming a generic pinout.
Properly sized DC distribution Busbars, disconnect, conductors, lugs, source protection, branch fuses, and precharge appropriate to the system.
24V lithium-compatible charge sources Inverter/charger, MPPT solar controllers, AC charger, and DC-DC equipment programmed to Epoch settings.
Replacement Eaton JJN-300 fuse Keep only the exact approved Class-T fuse and service procedure available for qualified maintenance.

Marine and ABYC installation note

A built-in Class-T fuse supports system safety—but compliance applies to the complete installation.

Installers searching for an ABYC-compliant marine battery system should evaluate the full design rather than the battery alone. Disconnect accessibility, source and branch protection, unfused conductor length, cable ampacity, securement, ignition-protection requirements, grounding, labeling, compartment conditions, and commissioning must all be addressed under the applicable standards and vessel design.

Technical Specifications

Electrical ratings, Class-T fuse data, communications, dimensions, heating, BMS protection, and charging settings.

Identification
Brand Epoch Batteries
Product 24V 230Ah V2-T Elite Series LiFePO4 Battery
Model / SKU C24230A-A
Series Epoch V2-T Elite Series
Battery duty Deep-cycle house power and energy storage; not an engine-starting battery
Chemistry LiFePO4 / lithium iron phosphate
Cell configuration 8S1P
Published warranty 11-year limited warranty: free repair or replacement in Years 1–5, then 40% off MSRP on a replacement battery in Years 6–11. Register within 90 days or keep your proof of purchase.
Voltage and Capacity
Nominal voltage 25.6V
Rated capacity 230Ah
Standard stored energy 5.888kWh / approximately 5.89kWh
Maximum voltage (planning) 29.0V; never charge above 29.0V
Minimum voltage (planning) 20.8V
Operating state of charge 0–100%
Internal resistance ≤16mΩ
Self-discharge rate ≤3% per month
Current Ratings
Continuous discharge current ≤115A
Continuous charge current ≤115A
Peak discharge 250A for 5 seconds
Maximum charge, short duration 180A for 5 seconds; 115A continuous for all charge sources combined
Nominal continuous DC output Approximately 2,944W at 25.6V before inverter losses
Standard charge (rating method) CC ≤0.5C, CV 3.60V per cell (28.8V), end at 0.02C. Use the recommended charger settings below (28.4V absorption, 27.0V float).
Integrated Class-T Fuse
Fuse type User-serviceable Eaton Class-T source fuse
Fuse model Eaton JJN-300
Amperage rating 300A
Interrupt rating 20kAIC at 160VDC
Voltage rating 300VAC / 160VDC
Short-circuit recovery Replace approved fuse after fault diagnosis and controlled isolation
System-design limitation Internal source fuse does not replace the main disconnect, downstream conductor protection, or branch protection
Series, Parallel and Communications
Supported standalone use Yes
Series connections Up to 2 identical C24230A-A batteries
Parallel connections Up to 16 identical C24230A-A batteries
Mixed series-parallel Not supported
Maximum parallel energy About 94.21kWh nominal (3,680Ah) with 16 batteries
Battery communication Bluetooth 4.0 and CAN-bus 500kbit/s
Victron integration Compatible GX device using the specified BMS communication harness and DVCC configuration
Network layout Daisy-chain; no branches or tee connections
Recommended Charging Settings
Bulk / absorption voltage 28.4V (every charge source, Victron equipment included)
Absorption time 15 minutes per battery in the bank
Float voltage 27.0V
Equalization Off / disabled
Temperature compensation Disabled
Victron setup Configure BMS-Can or VE.Can as instructed, enable DVCC, select Epoch as controlling BMS and battery monitor
Backup source programming Program MultiPlus, Quattro, MPPT, and other charge sources to the same safe values in case CAN communication is lost
Temperature and Heating
Charge temperature 0°C to 50°C / 32°F to 122°F, with heating support
Discharge temperature -20°C to 50°C / -4°F to 122°F
Storage, one month or less -20°C to 45°C / -4°F to 113°F
Storage, one year or less 0°C to 35°C / 32°F to 95°F
Heater power 153.6W
Heater voltage 29.2VDC
Charge low-temperature protection 0°C, with heating
Heater activation during charging 5°C
Heater deactivation during charging 10°C
Discharge low-temperature protection -20°C
Mechanical
Dimensions 20.86 × 8.65 × 12.06 in / 529.8 × 219.8 × 306.3mm
Weight 98.9 lb / 45.86kg
Case material PC + ABS, UL94 V-0
Terminals M8 bolts
Terminal torque 12N·m / 8.85lb-ft
Cooling Passive convection
Ingress protection IP67; dust-tight and temporary immersion ≤1m for ≤30 minutes with all seals/glands installed
Rated pressure 86–106kPa
BMS Protection Values
Charge overcurrent protection 180A ±2A with 5-second delay
Discharge overcurrent protection 250A ±2A with 5-second delay
Charge high-temperature protection / release 55°C / 53°C
Charge low-temperature protection / release 0°C / 5°C with heating
Discharge high-temperature protection / release 55°C / 53°C
Discharge low-temperature protection / release -20°C / -17°C
Balancing and monitoring Embedded BMS supervises cell voltage, current, temperature, protection, and balancing behavior
Lifecycle and Published Listings
Cycle life 3,500+ cycles to 70% end-of-life capacity (25°C)
End-of-life test capacity 70%
Published cell listings / standards UL1642, UL9540A, IEC 62619:2022
Other published compliance CE and RoHS; UN 3480, Class 9 (transport)
Published fuse-related listing UL60691 fuse component listed on product page

Ratings are from the C24230A-A spec sheet, technical data sheet and user manual (Rev V02, October 2026), at 25°C unless noted.

Installation and commissioning note

Secure the battery first, then engineer conductors, protection, precharge, charging, communications, and documentation.

Install on a flat rigid surface with service access to terminals, the fuse area, switch, and communication ports. Use approved restraints, short protected source conductors, appropriate busbars and lugs, controlled precharge for large capacitive loads, and equal-length conductors in parallel banks. Commission Victron communications, DIP settings, current limits, charging voltages, alarms, and module counts before placing loads into service.

Frequently asked questions

Epoch 24V 230Ah V2-T Elite Battery FAQs

Common questions about the Class-T fuse, Victron setup, heating, IP67 protection, inverter sizing, and bank expansion.

What does “V2-T” mean, and why is the Class-T fuse important?

The V2-T design adds a user-serviceable 300A Eaton Class T fuse to the V2 Elite platform. The C24230A-A uses an Eaton Bussmann JJN-300 rated at 300A with a 20kA interrupting rating at 160V DC, under a protected service cover on the lid. It reduces fault energy at the battery outlet, but it does not replace the main disconnect, downstream conductor protection, branch fusing, or the rest of a code-compliant system design.

If the internal Class-T fuse opens, is the battery ruined?

No. The fuse is replaceable through the protected service-access area. Isolate every source and load, open the main disconnect, verify the system is de-energized, identify and correct the fault, and replace the fuse only with the exact approved model and rating. Restore all covers and seals before returning the battery to service; qualified service is strongly recommended.

Does the 24V V2-T connect directly to a Victron system?

Yes, when installed with Epoch's specified communication harness and configuration. The battery communicates at 500kbit/s over CAN. Connect the designated grey RJ45 lead to the appropriate BMS-Can or configurable VE.Can port on a compatible Cerbo GX or Ekrano GX, set the port as instructed, enable DVCC, and select Epoch as the controlling BMS and battery monitor. Do not assume every generic RJ45 cable has the required battery-side pinout.

Can I connect these batteries in series or parallel?

The C24230A-A user manual supports up to two batteries in series (51.2V nominal, 58.0V at full charge) or up to sixteen in parallel (3,680Ah). Mixed series-parallel banks are not supported. Use C24230A-A batteries of the same age, capacity and state of charge (fully charge each one on its own first), set the DIP switches for the bank, and follow the manual for the selected topology.

How large can a parallel V2-T battery bank become?

Sixteen 5.888kWh batteries provide about 94.21kWh of nominal stored energy and 3,680Ah at 25.6V nominal. Every battery output is a separate source and requires an engineered connection to common busbars, equal-length conductors, appropriate source and branch protection, secure mounting, communication configuration, and professional commissioning.

How does internal self-heating work in freezing conditions?

The battery includes a 153.6W heater controlled by the BMS. The user manual lists low-temperature charge protection at 0°C, heater activation during charging at 5°C, and heater deactivation at 10°C. Available incoming charge energy warms the cells before normal charging proceeds. Charging equipment must still be programmed correctly and provide enough current for heating and charging.

Is the battery completely waterproof?

No. The enclosure is IP67 rated—dust-tight and tested for temporary immersion up to 1 meter for up to 30 minutes when all seals and glands are correctly installed. It is not rated for water jets, pressure washing or continuous submersion. Install the battery where it stays dry in normal use, and make sure all harness connectors are fully seated.

What size inverter can one 24V 230Ah V2-T battery support?

At 25.6V nominal and 115A continuous discharge, the battery provides approximately 2.94kW of nominal DC output before inverter losses. Inverter DC input current ≈ AC load ÷ (25.6V × inverter efficiency): a 2,000W load through a 90%-efficient inverter draws about 87A. If an inverter's continuous DC input can exceed 115A, add batteries in parallel. Final inverter sizing must account for efficiency, surge demand, cable voltage drop, ambient temperature, precharge requirements, downstream protection, and the battery's current limits.

Does the built-in fuse make the installation ABYC compliant?

No single component makes an entire installation ABYC compliant. The integrated Class T fuse reduces fault energy at the battery outlet but does not replace the main fuse, disconnect or branch protection; compliance depends on the complete system—including disconnect location, unfused conductor length, conductor ampacity, overcurrent protection, ignition-protection requirements where applicable, securement, routing, labeling, grounding, and qualified installation.

What can I monitor through Bluetooth?

The Epoch Cloud app (iOS and Android) shows state of charge, cell voltage, temperature, charge and discharge cycles and system health alerts, over Bluetooth 4.0 through the included battery gauge (stay within about 10 m). The gauge also shows state of charge. In a Victron-managed system, the GX device becomes the central view for battery and system data.

What are the dimensions and weight?

The user manual lists the C24230A-A at 20.86 inches long by 8.65 inches wide by 12.06 inches high, with a weight of 98.9 pounds. It uses M8 terminals with a published terminal torque of 12N·m (8.85lb-ft). Confirm compartment clearance, service access, cable bend radius, and mounting hardware before ordering.

Shipping times are in business days.

Please allow for 5-10 business days processing and shipping. You may receive your products in multiple shipments and packages. Currently we only ship to the Continental 48 states.

Additional shipping charges and requirements may apply to those outside the 48 states.

This site is protected by hCaptcha and the hCaptcha Privacy Policy and Terms of Service apply.


Recently viewed